modflow.infoHomeResourcesToolsExamplesSearchAbout

Groundwater Modelling Guidelines: What to Add to the MODFLOW Reviewer

Review of three national and provincial guidelines against the current modflow_review.py checks · 13 November 2026

Status, 13 November 2026. Implemented in the reviewer: Not implemented, by decision: See the README and MODFLOW_Reviewer_Documentation.html, "Guideline checks".

Summary

3
Guidelines reviewed
Australia 2013 companion, British Columbia 2012, Chile SEA 2012 (524 pages)
7 of 21
Numeric criteria already checked
5 more partly; mass balance, grid and aspect ratio, TSMULT, thickness, Peclet, Courant
14
New checks recommended
all from files the reviewer already reads
6
Larger additions
need a second model run or a user-supplied table

All three guidelines are mostly about process: objectives, conceptual model, reporting and review. Only a small part of each can be checked from model files. Where they do give checkable criteria, the reviewer already covers most of them, often with the same or a stricter threshold. Examples are the 0.5–1% mass-balance limit, grid-spacing ratio, cell aspect ratio, Peclet and Courant numbers, time-step multiplier, initial-condition drift, specified heads supplying pumping, and residual normality and clustering.

The guidelines do point to gaps in four areas:

One caution runs through all three documents. Calibration targets are meant to be agreed per project, not applied as fixed pass/fail rules: Any thresholds added from these guidelines should therefore be notes or warnings that name their source, and every value should be configurable with --set. None of them should be errors.

Top recommendations

#AdditionSourceEffort
1Calibration statistics: R², scaled mean absolute error against Chile's 5% bound, NRMSE grade bands (under 5%, under 10%), and a count of flux targets within 15%BC 7.3; Chile p. 43; BC case study 3Low
2Head-target quality: observed head above land surface or below the cell bottom; targets in specified-head cells; distance from each target to the nearest boundary cellBC p. 156–158, 164, App. F; Chile p. 37Low
3Depth-to-water residual statistics beside the head statistics, for models with high reliefBC p. 155–157Low
4Evapotranspiration superimposed on specified-head or head-dependent boundary cells; EVT extinction depth above about 5 mAustralia App. A 5.7.3; BC p. 63Low
5River cells disconnected from the aquifer (head below river bottom), and a gaining/losing/disconnected summary per river reach or SFR segmentChile p. 104; BC p. 63Medium
6Specified-head and GHB cells: per-cell flow ranking, single cells supplying a large share of inflow, and cells whose flow reverses between the first and last budgetBC p. 136; Chile p. 102Medium
7Dispersivity plausibility (αL 2–10 m at basin scale, αT ≈ 0.1 αL, αV lower again) and a flag for the code-default 10/1/0.1 m setBC p. 204, 220–221Low
8Baseline-versus-prediction mode: drawdown extent, drawdown reaching boundaries, change in boundary and stream flows, and predicted drawdown compared with calibration errorAll threeHigh

Documents reviewed

DocumentPublisher, yearPagesCharacterChecklists
Australian groundwater modelling guidelines – Companion to the guidelinesNational Water Commission (SKM), 201331Plain-language summary of Barnett et al. (2012), with the guiding principles and clarificationsCompliance checklist (Table 2); model review checklist (Appendix A, about 120 questions)
Guidelines for Groundwater Modelling to Assess Impacts of Proposed Natural Resource Development ActivitiesBC Ministry of Environment (Wels, Mackie, Scibek), 2012385Full technical guideline: setup, calibration, prediction, transport, review, three case studiesTables D1 appraisal, D2 compliance (PASS/FAIL), D3 peer review (9 pages); Appendix F target-quality tables
Guía para el uso de modelos de aguas subterráneas en el SEIAServicio de Evaluación Ambiental, Chile, 2012108Environmental-assessment guide; mostly conceptual-model and reporting requirements, plus a technical annexTable 4 (conceptual model), Table 11 (numerical model), Table 12 (predictive capacity), minimum report content (§5)

Page numbers in this report are PDF page numbers. For the BC guideline, the printed page is the PDF page minus 13 in the main body. For the Chilean annex, the printed page is the PDF page minus 67.

Numeric criteria compared with the reviewer

These are every numeric criterion in the three documents that applies to MODFLOW files, together with the reviewer's current setting.

CriterionAustraliaBritish ColumbiaChileReviewer nowStatus
Global mass-balance error–< 0.5% (p. 145)< 1% at the end of each stress period (p. 43, 46, 57)Every printed budget; warning above 0.5%, error above 1%; discrepancy-versus-time plotCovered
Head calibration, scaled RMS / NRMSE5% or 10% only if known to be achievable (§5.4)< 10% good, < 5% very good (p. 163)–Warning above 10% (calib_scaled_rms_pct)Partial add the 5% band as a note
Mean absolute error–MAE and NMAE to be reported (p. 154)MAE ≤ 5% of the observed head range, as an upper bound (p. 43)Scaled absolute mean computed, no criterionPartial
Correlation of observed and simulated–R ≥ 0.95, with caveats about outliers and few points (p. 155)–Not computedNew
Flux targets–Within 15% of measured (case study, p. 363)–Warning when the median absolute error exceeds 25%Partial
Adjacent cell size ratio–"Gradual" (no number)0.5–2 (p. 100)1.5 (structured), 2.5 (DISV/DISU)Covered
Cell aspect ratio––1:10 to 10:1 (p. 100)10Covered
Time-step multiplier–1.2–1.5 (p. 144)–Warning above 1.5Covered
Simulation length––At least 1 year, monthly, if seasonal (p. 34)Not checkedNew (note)
Minimum layer thickness––10–20% of the mean, as a dry-cell remedy (p. 33)< 1 unit or < 5% of the layer medianCovered keep 5%
Specific yield––0.02–0.3 unconfined; Table 2 gives 0.01–0.47 (p. 77)Warning outside 0.001–0.5Partial note below 0.01
Confined storage coefficient––S < 0.005 (p. 77–78)Error at S ≥ 1; warning if Ss > 1e-2Partial note above 0.005
Hydraulic conductivity–Within field-test ranges (p. 148–149)About 1e-8 (clay) to 1,000 m/d (gravel) (p. 75)Invalid (≤ 0) K, Kv > Kh, Kh/Kv > 1000New plausibility note
ET extinction depth–Root zone about 1–5 m (p. 63)Segmented ET curve preferred (p. 35, 103)Not checkedNew
Grid Peclet number–1–4, depending on the scheme (App. E)< 2 (p. 101); Table 6 also gives < 10 / < 52Covered
Courant number–≤ 1 (App. E)< 1, not relevant in steady state (p. 100–101)1Covered
Neumann number D·Δt/Δx²––< 0.5 (p. 101)Not computedNew
Dispersivity–αL 2–10 m at basin scale; αT ≈ αL/10; αV ≈ αL/10–αL/100 (p. 204)–Used only for the Peclet numberNew
Density-dependent grid–Cell width 0.38% of domain length, thickness 0.60% of domain height (p. 123)–Not checkedNew (low priority)
Calibration / validation splitVerification only with plenty of data (§5.6)Reserved data set, not an artificial split (p. 165)Records > 10 years: 70/30; under 5 years: all for calibration plus sensitivity analysis (p. 39)Not supportedNew (needs input)
Impact thresholds–Drawdown 0.1 m zone of influence; baseflow change > 10% (case study, p. 364)Environmental systems sensitive to < 1 m (p. 51)Not supportedNew (needs baseline run)

Guideline items the reviewer already covers

Guideline itemWhereReviewer check
Superimposed boundary conditions in one cell (wells in constant-head cells, etc.)Chile p. 35Check 1 and "BCs in constant-head cells"
Constant heads as unlimited sources or sinks; inspect the budgetChile p. 35, 102; BC p. 136Budget composition, constant-head share
Specified heads near pumping wells hide drawdownChile p. 102–103; BC p. 118, 125Source of water to wells (Reilly 2001)
Steady-state model needs at least one specified headBC p. 125, 145Ill-posed model check
Pumping rates in input equal to modelled ratesAustralia App. A 5.7.1; Chile p. 45, 55–56Automatic well-flow reduction
Imposed versus read recharge (dry-cell losses)Chile p. 33, 55Applied recharge compared with budget recharge
Initial heads chosen so early times are not wrong; effect of initial conditionsAustralia 4.5, App. A 3.6; BC p. 142–143; Chile p. 36Initial-condition drift
Solver, convergence criteria judged by mass balanceAustralia App. A 3.7; BC p. 145Checks 7, 8 and 11
Vertical gradients reproducedAustralia App. A 4.4.2Head-difference targets, wrong-sign pairs
Calibration plotted spatially and through time; histogram centred on zero; systematic biasAustralia App. A 4.5; BC p. 156–158; Chile p. 47Residual maps, normality (R2N), trend, Moran's I, runs test
Observation wells inside the active domainChile p. 37Targets in inactive or dry cells
Concentrations spanning orders of magnitudeChile p. 41–42Log-scale concentration calibration
Water table above ground from recharge or no-flow moundingBC p. 135–136Heads above land surface; recharge versus K
Pinch-outs not as zero thicknessBC p. 123Check 5 (zero thickness is an error)
Confined simplification where the water table falls below the topBC p. 99, 145Confined layers below cell top
Time steps per stress periodAustralia App. A 3.4.3; BC D3 4.13NSTP and TSMULT check; adaptive time stepping reported
Calibrated parameter ranges tabulated for auditBC p. 236–237Per-layer property summary
All processes in the conceptual model activatedBC p. 236–237Package classification (reviewed, passive, not reviewed)
Unit errors in flux targets (per day versus per second)BC App. FFlux-target unit-mix check
Transport stability, numerical dispersionBC App. E, p. 209–211; Chile p. 100–101Grid Peclet and Courant numbers

Recommended additions that use data the reviewer already reads

Priority: High clear guideline basis and cheap; Medium useful, some design needed; Low narrow or informational.

  1. Calibration statistics aligned with the guidelines High
    Add the correlation coefficient R and R² to the overall and per-layer statistics, with BC's 0.95 reference shown as a note. Add the scaled mean absolute error checked against Chile's 5% upper bound. Grade the scaled RMS in BC's bands (under 5% very good, under 10% good). Keep the current 10% warning. Report the share of flux targets within 15%.
    BC p. 154–155, 163, 363; Chile p. 43, 105; Australia §5.4. Source: the existing *_targets_resids.csv files. Every value configurable.
  2. Head-target quality checks High
    Flag observed heads above land surface (top of layer 1) or below the bottom of the assigned cell. These usually mean a casing-stickup, datum or layer-assignment error. Flag targets in specified-head cells, which fit by construction and inflate the statistics (one of BC's over-calibration signs). Give each target's distance in cells to the nearest specified-head, GHB or river cell, so boundary-controlled targets can be seen. If the target file has a screen-elevation column, check that the screen lies inside the layer.
    BC p. 149, 156–158, 164, Appendix F (Table F1); Chile p. 37.
  3. Depth-to-water residuals Medium
    In high-relief models, a scaled RMS based on head elevation can look excellent while depth-to-water errors are large. BC's example gives 3.5% on head elevation against 23% on depth to water. Report mean, absolute mean, RMS and scaled RMS computed on depth to water (cell top minus head) beside the head versions. Also show the absolute residual range in length units as a "reality check".
    BC p. 155–157, 164.
  4. Evapotranspiration on boundary cells and ET settings High
    Flag EVT, ETS or UZF-ET cells that are also specified-head cells, or that hold GHB, RIV or DRN boundaries. In a constant-head cell, ET draws from an unlimited supply. The Australian checklist names this superposition as a source of anomalous boundary fluxes. Also flag extinction depths above about 5 m. Report whether EVT (one linear segment) or ETS (several segments) is used, since Chile prefers a segmented ET curve.
    Australia App. A 5.7.3; BC p. 63; Chile p. 35–36, 103.
  5. River–aquifer connection Medium
    For RIV and SFR cells, classify each cell at the final time step:
    • gaining: head above stage;
    • losing: head between the river bottom and stage;
    • disconnected: head below the river bottom, where leakage is fixed at C·(stage − bottom).
    Report the counts and flow per class, and the total infiltration from disconnected cells. Chile warns that a river over a deep water table can overstate infiltration. Give a per-reach (SFR segment, or RIV block) exchange table so calibration to baseflow and to gaining and losing reaches can be checked.
    Chile p. 36–37, 104 (Table 16); BC p. 63, 160.
  6. Specified-head and GHB cell behaviour Medium
    Rank specified-head and GHB cells by flow, and flag any single cell, or connected group of cells, that supplies more than a set share of total inflow. BC notes that one misplaced specified-head cell can supply a large volume of water. In transient models, flag cells whose flow reverses sign between the first and last saved budget. Chile describes a discharge boundary that turns into a recharge source as heads fall. Flag specified heads below the cell bottom or far above land surface.
    BC p. 132, 136–137; Chile p. 102–103.
  7. Storage dominated by isolated recharge cells Medium
    In transient models, report the share of the storage change carried by the top 1% of cells. Flag cases where it is concentrated in recharge cells with rising heads. The Australian checklist asks whether storage changes are dominated by anomalous head increases in isolated cells that receive recharge.
    Australia App. A 5.7.5.
  8. Property plausibility Medium
    Add a note when Kh or Kv falls outside about 1e-8 to 1,000 m/d (converted from the model units), when a confined layer has S above 0.005, or when Sy is below 0.01. Report the number of distinct K and recharge values per layer, so cell-by-cell fields stand out, and compare it with the number of calibration targets. BC warns about over-parameterisation, and Chile asks for the fewest parameters needed.
    Chile p. 39–40, 75, 77–78; BC p. 140, 148–149, 164; Australia §5.3.
  9. Vertical discretisation of aquitards Low
    In transient models, flag thick low-Kv layers (aquitards) that are a single model layer. One layer cannot reproduce the delay in vertical propagation of responses. The thresholds would be ours, because the guideline asks the question without giving a number.
    Australia App. A 3.3.5.
  10. Disconnected active regions and inactive holes Medium
    Extend the isolated-cell check to connected components:
    • flag groups of active cells that are cut off from the main body;
    • flag such groups that have no boundary condition (singular unless a head-dependent boundary is present);
    • flag inactive "holes" inside an otherwise active layer.
    Chile p. 33; BC p. 228.
  11. Rewetting reported Low
    Report when rewetting is on (BCF/LPF WETDRY with IWDFLG, MF6 REWET), with the note that it can cause instability. The solver advice already mentions WETDRY when drying and rewetting events appear in the listing. This would make the setting visible even when no events occur.
    Chile p. 33 (footnote 14); BC p. 99.
  12. Transport parameter plausibility High for USG-Transport and GWT models
    Read the dispersivity arrays the reviewer already uses for the Peclet number. Flag the following:
    • longitudinal dispersivity outside 2–10 m at basin scale (configurable);
    • transverse dispersivity not lower than longitudinal, or vertical dispersivity above horizontal transverse;
    • uniform values equal to the common code defaults (10, 1 and 0.1 m), which BC criticises in its case study 2.
    Add the Neumann number D·Δt/Δx² < 0.5 next to Peclet and Courant. Skip the Courant warning for steady-state flow fields, as Chile notes it doesn't apply there.
    BC p. 204, 209–211, 220–221, Appendix E; Chile p. 100–101.
  13. Time horizon Low
    Add a note when a transient model covers less than one year or uses stress periods much longer than a month while recharge or ET varies, and report total simulated time. Chile asks for at least one year of monthly information in seasonal systems.
    Chile p. 34, 38; BC p. 144.
  14. Density-dependent grid size Low
    For DDF models, compare cell width with 0.38% of the domain length and layer thickness with 0.60% of the domain height. Check that specified heads in saline zones are equivalent freshwater heads.
    BC p. 123, 132–133.

Recommended additions that need extra input

  1. Baseline-versus-prediction comparison mode High
    All three guidelines judge an impact model by comparing a prediction run with a baseline (no-project) run. A --baseline option pointing at a second model would let the reviewer do the following:
    • map drawdown and report the area above 0.1 m and 1 m (configurable);
    • flag drawdown that reaches the model edge or specified-head cells, which would mean the boundary is too close;
    • report the change in each boundary and stream flow, and flag stream baseflow reductions above 10%;
    • compare the largest predicted drawdown with the calibration error, and flag drawdowns smaller than the calibration MAE;
    • compare pumping rates, recharge and run length in the prediction with the calibration run. The Australian checklist asks whether predictive stresses and time scales are similar to calibration. This overlaps the "prediction-stress extrapolation" candidate already in Groundwater_Model_Review_Literature.html;
    • list input differences between the two runs (K, recharge, boundaries, packages).
    Chile p. 44, 51, 60; BC p. 118, 125, 175–180, 364, D3 7.4–7.10; Australia App. A 5.4–5.5.
  2. Conceptual water balance comparison Medium
    Accept an optional CSV of expected budget terms, each with a low and high range (BC Table 4-1 format). Flag simulated terms outside their range. Both BC and Chile require calculated boundary flows to be checked against the conceptual balance.
    BC p. 65–66; Chile p. 35, 102.
  3. Calibration and verification split Medium
    Honour an optional "set" column in the target files (calibration or verification). Report the statistics side by side, and flag a verification error much larger than the calibration error. If the target files carry dates, report the record length so Chile's 70/30 rule can be applied.
    BC p. 165–166, D3 6.1–6.11; Chile p. 39, 43; Australia §5.6.
  4. Per-target hydrograph metrics Medium
    For transient targets, add the following for each target:
    • bias-removed RMSE;
    • correlation of the observed and simulated series;
    • lag at maximum cross-correlation, showing whether the model responds too fast or too slowly;
    • statistics on drawdown from the initial head.
    BC notes that a high R² can hide a datum offset.
    BC p. 161–163.
  5. Starting heads against a steady-state solution Low
    When a steady-state head file of the same grid is supplied, compare it with the transient starting heads. BC prefers model-generated starting heads to interpolated observations.
    BC p. 142–143; Australia App. A 3.6.1.
  6. Recharge against rainfall Low
    Report recharge in mm/yr (overall and by zone). With an optional rainfall value, flag recharge that exceeds it.
    Australia App. A 5.7.4; BC p. 60–61; Chile p. 23, 27.

Report-format recommendations

  1. Guideline checklists as optional report appendices Medium
    The report already ends with the USGS SIR 2004-5038 reviewer questions. Optional appendices could reproduce the Australian Appendix A checklist, BC Tables D2 and D3, and Chile Tables 11 and 12. For questions a check answers, the reviewer would suggest an answer and link the finding. Examples: convergence and water balance (BC D3 5.5), pumping rates as modelled (Australia 5.7.1), and imposed versus read flows (Chile Table 12). BC's answer scale is N/A, Missing, Deficient or Adequate. All other questions would be left blank for the modeller. This would let a modeller hand a regulator a partly completed checklist in the required format. A --checklist au|bc|cl|usgs option would choose which one.
  2. Model description table Low
    The reviewer reads most of what Chile's Table 11 and BC's Table 10-1 item 6 ask a report to describe: grid origin and rotation, rows, columns, layers, cell sizes, steady or transient, stress periods, boundary types, and property distributions. A single "model description" table in that order would save the modeller time. Much of it is already in Model information.
  3. Complexity indicators, not a classification Low
    BC defines Basic, Moderate and Complex models, and Australia defines confidence Classes 1–3. Both depend largely on data and on how a model is used, which the files can't show. The reviewer could list the observable indicators: target counts and types, flux targets, transient calibration, a verification set, presence of parameter-estimation files, and multiple scenarios. It should leave the classification to the reviewer.

Not recommended for the reviewer

Limits of this review